B1B0D-Passanger Airbag squib 2 circuit high
May 15, 2017
Add Comment
B1B0D code - The Occupant Restraint Contoller (ORC) monitors the voltage of the Passanger squib 2 circuits. The ORC will set this DTC if it detects voltage on the Passanger squib 2 circuits.
Possible causes B1B0D code:
- Passanger squib 2 line 1 circuit shorted to Battery.
- Passanger squib 2 line 2 circuit shorted to Battery.
- Passanger Airbag.
- Occupant Restraint Controller (ORC or Airbag Module).
Step by step diagnostic DTC B1B0D-Passanger Airbag squib 2 circuit high
Step 1. Determine active or stored DTC
Note : Make sure that the battery is fully charged.
Turn the ignition on, with the scan tool, read the active ORC DTC.
Select active or stored DTC B1B0D code :
Active, go to step 2.
Stored, go to step 4.
Step 2. Check for shorted squib circuits in passanger Airbag
Step 2. Check for shorted squib circuits in passanger Airbag
Warning : Turn the ignition off, disconnect the 12 volts battery and wait two minutes before proceeding. Failure to follow these instructions may result in possible serious or fatal injury.
Disconnect the Passanger Airbag squib connectors.
Warning : Do not place in intact non deployed Airbag face down on a hard surface, the Airbag propels into the air if accidentally deployed. Failure to follow these instructions may result in possible serious fatal injury.
Note : Check connectors, clean and repair as neccesary.
Connect the SRS load tool kit and SRS load tool jumper to the Passanger Airbag squib connectors.
Warning : Turn the ignition on, then reconnect the 12 volt battery and wait two minutes before continuing. Failure to follow these instructions may result in possible serious or fatal injury.
With the scan tool, read the active ORC DTC.
Does the scan tool display code B1B0D-Passanger Airbag squib 2 circuit high DTC ?
Yes, go to step 3.
No, replace the Passanger Airbag. Perform the Airbag system verification.
Step 3. Check Passanger squib 2 line 1 circuit and Passanger squib 2 line 2 circuit for a short to Battery
Warning : Turn the ignition off, disconnect the 12 volt battery and wait two minutes before proceeding. Failure to follow these instructions may result in possible serious or fatal injury.
Disconnect the SRS load tool kit and SRS load tool jumper from the Passanger Airbag squib connectors, disconnect the ORC connector.
Note : Check connectors, clean and repair as neccesary.
Connect the SRS load tool adaptor to the ORC connector.
Warning : Turn the ignition on, then reconnect the 12 volt battery and wait two minutes before proceeding. Failure to follow these instructions may result in possible serious or fatal injury.
Measure the voltage of the Passanger squib 2 line 1 circuit between the SRS load tool adaptor, and measure the voltage of the Passanger Squib 2 line 2 circuit between SRS load tool adaptor.
Is there any voltage present on either circuit ?
Yes, Warning : Turn the ignition off, disconnect the 12 volt battery and wait two minutes before proceeding. Failure to follow these instructions may result in possible serious or fatal injury.
Repair the Passanger squib 2 circuits with voltage present for a short to battery.
No, Warning : If the Occupant Restraint Controller (ORC) is dropped at any time, it must be replaced. Failure to follow these instructions may result in possible serious or fatal injury.
Replace the Occupant Restraint Controller (ORC). Perform the Airbag system verification.
Step 4. Checking stored or intermittent codes
Note : Diagnose and repair all active codes before diagnosing stored.
With the scan tool, record and erase all Airbag system module DTC.
Warning : Turn the ignition off, disconnect the 12 volt battery and wait two minutes before proceeding. Failure to follow these instructions may result in possible serious or fatal injury.
Using the wiring diagram/schematic as a guide, inspect the related wiring and connectors for chafed, pierced, pinched, and partially broken wires, and for broken, bent, pushed out, corroded, and contaminated terminals. Repair as neccesary.
Reconnect all disconnected components and harness connectors.
Warning : Turn the ignition on, then reconnect 12 volt battery and wait two minutes before proceeding. Failure to follow these instructions may result in possible serious or fatal injury.
With the scan tool, monitor for active codes while performing the following :
- Wiggle the wiring harness connectors of the related airbag circuit.
- Continuing the test until either a code becomes active or the problem area is isolated.
Are any active DTC present ?
Yes, perform the appropriate diagnostic procedure.
No, no problem found at this time. Erase all codes before returning the vehicle to the customer.
Test complete for the DTC B1B0D-Passanger Airbag squib 2 circuit high.
0 Response to "B1B0D-Passanger Airbag squib 2 circuit high"
Post a Comment